Página 2 - Important Safety Information

10Burner Dia. Tap By-pass1/100 mmAuxiliary 28Semi-rapid 32Rapid 42Aeration adjustment noneOVERALL DIMENSIONS Width: 580 mm.Depth: 510 mm.Height: 88 mm

Página 3 - Environmental Information

11BURNER RAPID SEMI-RAPID AUXILIARY(large) (medium) (small)POSITION MAX MIN MAX MIN MAX MIN NOMINAL THERMAL POWER kW 2.9 0.75 1.9 0.45 1

Página 4 - Contents

12LocationThe hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in abathroom or shower room.Before making the cut out in t

Página 5 - Description of the Hob

13InstallationIMPORTANTThis hob must be installed by a competent person to the relevant GasStandards.Any gas installation must be carried out by a reg

Página 6 - Operation

14It is important to install the elbow correctly, with the shoulder on the end of thethread, fitted to the hob connecting pipe.Failure to ensure the c

Página 7 - Maintenance and Cleaning

15550470580510Cut Out SizeThe dimensions of the cut-out are given in the diagram.Building InBuilding over a cupboard ordrawerIf the hob is to be insta

Página 8 - Ignition electrode

16Building over a kitchen unit with doorProper arrangements must be taken indesigning the furniture unit, in order toavoid any contact with the bottom

Página 9 - Something Not Working?

17Electrical connectionsAny electrical work required to install this hob should be carried out by a qualifiedelectrician or competent person, in accor

Página 10 - Engineer technical data

18Wiring diagram1. TAPS IGNITOR SWITCHES2. IGNITOR UNIT3. LED POWER INDICATORSPermanent ConnectionIn the case of a permanent connection, it is necessa

Página 11 - Important safety requirements

19Fault FindingPreliminary Electrical Systems CheckSTARTIsolate applianceand carry out:A: Earth Continuitycheck. Has inlet fuse blown?Carry out:C: Pol

Página 12 - Location

2Important Safety InformationYou MUST read these warnings carefully before installing or using thehob. If you need assistance, contact our Customer Ca

Página 13 - Installation

20A. EARTH CONTINUITY CHECKAppliance must be electrically disconnected - meter set on Ω (Ohms) x 1 scale andadjust zero if necessary.— Test leads fro

Página 14 - Gas Connection

21Check gas supply atburnerIgnition System / Gas IgnitionYESCheck plug top fuse andreplace if necessaryCheck polarity and earthcontinuity of supply po

Página 15 - Building In

22CommissioningWhen the hob has been fully installed it will be necessary to check the minimum flamesetting. To do this, follow the procedure below.1)

Página 16

23Conversion from Natural Gas to LPGIMPORTANTThe replacement/conversion of the gas hob should only be undertaken by a competentperson.It is important

Página 17 - Electrical connections

24Guarantee ConditionsStandard guarantee conditionsWe, AEG-Electrolux, undertake that if within 12 months of the date of the purchase this AEG-Electro

Página 18 - Wiring diagram

25Service and Spare PartsBefore calling out an engineer, please ensure you have read the details under the heading“Something not working”When you cont

Página 19 - Fault Finding

26European GuaranteeThis appliance is guaranteed by Electrolux in each of the countries listed at the back of thisuser manual, for the period specifie

Página 21

35686-0004 10/06Grafiche MDM - Forlìwww.aeg-electrolux.co.uk

Página 22 - Commissioning

3it has been installed. Ensure there is a continuous air supply, keeping air vents ingood condition or installing a cooker hood with a venting hose.!

Página 23 - To adjust the gas rate

4ContentsImportant Safety Information ... 2Instructions for the User ...

Página 24 - Guarantee Conditions

51. Hob Top2. Rapid Burner3. Semi-rapid Burners4. Auxiliary Burner5. Control knob for back right burner (semi-rapid)6. Control knob for back left burn

Página 25 - Customer Care

6Burner minimum maximumdiameter diameterLarge (rapid) 160 mm. 260 mm.Medium (semi-rapid) 120 mm. 220 mm.Small (Auxiliary) 80 mm. 160 mm.OperationAs so

Página 26 - European Guarantee

7Fig. 2Fig. 1YESNOFig. 2Maintenance and CleaningBefore any maintenance or cleaning can be carried out, you must DISCONNECT thehob from the electricity

Página 27

8The BurnersThe burner caps and crowns can be removed for cleaning. Wash the burner caps andcrowns using hot soapy water, and remove marks with a mild

Página 28 - Grafiche MDM - Forlì

9Something Not Working?If the hob is not working correctly, please carry out the following checks beforecontacting your local Service Force Centre.