CAUTION!
Do not connect the cable
without cable end sleeve.
Two-phase connection
1. Remove the cable end sleeve from
black and brown wires.
2. Remove an insulation of the brown
and black cable ends.
3. Apply a new wire end sleeve of 1.5
mm² on each cable end. (special tool
required).
Cable cross section
N
L1
N
L
230V~ 400V 2~N
L2
One-phase connection - 230 V~ Two-phase connection - 400 V 2 ~ N
Green - yellow Green - yellow
N Blue and blue Blue and blue N
L Black and brown Black L1
Brown L2
8.4 Assembly
min.
50mm
min.
500mm
R 5mm
min.
55mm
560
+1
mm
490
+1
mm