Make sure that there is an access to
the mains plug after installation.
Do not pull the mains cable to discon-
nect the appliance. Always pull the
mains plug.
The appliance must not be connected
with an extansion cable, an adapter or
a multiple connection (risk of fire).
Check that the ground connection is
in conformity with the standard and
regulations force.
The power cable must be placed in
such a way that it does not touch any
hot part.
Connect the appliance to the mains
with a device that lets to disconnect
the appliance from the mains at all
poles with a contact opening width of
minimum 3 mm, eg. automatic line
protecting cut-out, earth leakage trips
or fuse.
None of a parts of the connection ca-
ble can not get a temperature 90°C.
8.5 Replacement of the
connection cable
In order to replace the connection cable
speak your local Service Force Centre!
To replace the connection cable use on-
ly H05BB-F Tmax 90°C (or higher) type.
Make sure that the cable section is appli-
cable to the power and the working tem-
perature. The yellow/green earth wire
must be approximately 2 cm longer than
all phase wires.
8.6 Assembly
min.
450mm
min.
650mm
340
+1
mm
490
+1
mm
R 5mm
55mm