AEG BH8.04 Manual do Utilizador Página 13

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 26
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 12
13
Burner Dia. Tap By-pass Tap colour
1/100 mm
Auxiliary 28 Red/Red
Semi-rapid 32 Blue/Blue
Rapid 40 Black/Black
Double-Crown 56 Black/Red
Aeration adjustment none
BURNER RAPID SEMI-RAPID AUXILIARY DOUBLE
(large) (medium) (small) CROWN
POSITION MAX MIN MAX MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.0 0.65 2.0 0.45 1.0 0.33 3.5 1.2
NOMINAL FLOW
RATE m
3
/h 0.286 0.057 0.190 0.038 0.095 0.028 0.333 0.114
NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust. 136 Adjust.
1/100 mm
NOMINAL THERMAL
POWER kW 2.8 0.65 2.0 0.45 1.0 0.33 3.5 1.2
NOMINAL FLOW
RATE g/h 202 43.5 144 29 72 21,5 252 86
NOZZLE REFERENCE 86 40 71 32 50 28 93 56
1/100 mm
NATURAL GAS
20 mbar
VALUE =
37.78 MJ/m
3
Ws - 50.7 MJ/ m
3
TYPE OF GAS
LPG GAS
28-30/37 mbar
VALUE =
49.92 MJ/Kg
Vista de página 12